Marvell Armada 370 and Armada XP Timers
Required properties:
- compatible: Should be “marvell,armada-370-xp-timer”
- interrupts: Should contain the list of Global Timer interrupts and
then local timer interrupts - reg: Should contain location and length for timers register. First
pair for the Global Timer registers, second pair for the
local/private timers. - clocks: clock driving the timer hardware
Optional properties:
- marvell,timer-25Mhz: Tells whether the Global timer supports the 25
Mhz fixed mode (available on Armada XP and not on Armada 370)