Omap2/3 intc controller
On TI omap2 and 3 the intc interrupt controller can provide
96 or 128 IRQ signals to the ARM host depending on the SoC.
Required Properties:
compatible: should be one of
"ti,omap2-intc" "ti,omap3-intc" "ti,dm814-intc" "ti,dm816-intc" "ti,am33xx-intc"
interrupt-controller : Identifies the node as an interrupt controller
#interrupt-cells : Specifies the number of cells needed to encode interrupt
source, should be 1 for intc
interrupts: interrupt reference to primary interrupt controller
Please refer to interrupts.txt in this directory for details of the common
Interrupt Controllers bindings used by client devices.
Example:
intc: interrupt-controller@48200000 {
compatible = “ti,omap3-intc”;
interrupt-controller;
#interrupt-cells = <1>;
reg = <0x48200000 0x1000>;
};