Kernel-4.18.0-80.el8_mlx90614

  • Melexis MLX90614 contactless IR temperature sensor

http://melexis.com/Infrared-Thermometer-Sensors/Infrared-Thermometer-Sensors/MLX90614-615.aspx

Required properties:

  • compatible: should be “melexis,mlx90614”
  • reg: the I2C address of the sensor

Optional properties:

  • wakeup-gpios: device tree identifier of the GPIO connected to the SDA line
    to hold low in order to wake up the device. In normal operation, the
    GPIO is set as input and will not interfere in I2C communication. There
    is no need for a GPIO driving the SCL line. If no GPIO is given, power
    management is disabled.

Example:

mlx90614@5a {
compatible = “melexis,mlx90614”;
reg = <0x5a>;
wakeup-gpios = <&gpio0 2 GPIO_ACTIVE_HIGH>;
};