- Broadcom’s IPROC Static ADC controller
Broadcom iProc ADC controller has 8 channels 10bit ADC.
Allows user to convert analog input voltage values to digital.
Required properties:
compatible: Must be “brcm,iproc-static-adc”
adc-syscon: Handler of syscon node defining physical base address of the
controller and length of memory mapped region.#io-channel-cells = <1>; As ADC has multiple outputs
refer to Documentation/devicetree/bindings/iio/iio-bindings.txt for details.io-channel-ranges:
refer to Documentation/devicetree/bindings/iio/iio-bindings.txt for details.clocks: Clock used for this block.
clock-names: Clock name should be given as tsc_clk.
interrupts: interrupt line number.
For example:
ts_adc_syscon: ts_adc_syscon@180a6000 {
compatible = "brcm,iproc-ts-adc-syscon","syscon";
reg = <0x180a6000 0xc30>;
};
adc: adc@180a6000 {
compatible = "brcm,iproc-static-adc";
adc-syscon = <&ts_adc_syscon>;
#io-channel-cells = <1>;
io-channel-ranges;
clocks = <&asiu_clks BCM_CYGNUS_ASIU_ADC_CLK>;
clock-names = "tsc_clk";
interrupts = <GIC_SPI 164 IRQ_TYPE_LEVEL_HIGH>;
};