Broadcom BCM7038 PWM controller (BCM7xxx Set Top Box PWM controller)
Required properties:
- compatible: must be “brcm,bcm7038-pwm”
- reg: physical base address and length for this controller
- #pwm-cells: should be 2. See pwm.txt in this directory for a description
of the cells format - clocks: a phandle to the reference clock for this block which is fed through
its internal variable clock frequency generator
Example:
pwm: pwm@f0408000 {
compatible = "brcm,bcm7038-pwm";
reg = <0xf0408000 0x28>;
#pwm-cells = <2>;
clocks = <&upg_fixed>;
};