Kernel-4.18.0-80.el8_spi-dw

Synopsys DesignWare SPI master

Required properties:

  • compatible: should be “snps,designware-spi”
  • #address-cells: see spi-bus.txt
  • #size-cells: see spi-bus.txt
  • reg: address and length of the spi master registers
  • interrupts: should contain one interrupt
  • clocks: spi clock phandle
  • num-cs: see spi-bus.txt

Optional properties:

  • cs-gpios: see spi-bus.txt

Example:

spi: spi@4020a000 {
compatible = “snps,designware-spi”;
interrupts = <11 1>;
reg = <0x4020a000 0x1000>;
clocks = <&pclk>;
num-cs = <2>;
cs-gpios = <&banka 0 0>;
};