- Samsung Image Rotator
Required properties:
compatible : value should be one of the following:
(a) “samsung,exynos4210-rotator” for Rotator IP in Exynos4210
(b) “samsung,exynos4212-rotator” for Rotator IP in Exynos4212/4412
(c) “samsung,exynos5250-rotator” for Rotator IP in Exynos5250reg : Physical base address of the IP registers and length of memory
mapped region.interrupts : Interrupt specifier for rotator interrupt, according to format
specific to interrupt parent.
clocks : Clock specifier for rotator clock, according to generic clock
bindings. (See Documentation/devicetree/bindings/clock/exynos*.txt)
clock-names : Names of clocks. For exynos rotator, it should be “rotator”.
Example:
rotator@12810000 {
compatible = “samsung,exynos4210-rotator”;
reg = <0x12810000 0x1000>;
interrupts = <0 83 0>;
clocks = <&clock 278>;
clock-names = “rotator”;
};