- Microchip PIC32 Watchdog Timer
When enabled, the watchdog peripheral can be used to reset the device if the
WDT is not cleared periodically in software.
Required properties:
- compatible: must be “microchip,pic32mzda-wdt”.
- reg: physical base address of the controller and length of memory mapped
region. - clocks: phandle of source clk. Should be <&rootclk LPRCCLK>.
Example:
watchdog@1f800800 {
compatible = "microchip,pic32mzda-wdt";
reg = <0x1f800800 0x200>;
clocks = <&rootclk LPRCCLK>;
};