Marvell Armada 370 and Armada XP Timers
Required properties:
- compatible: Should be one of the following
"marvell,armada-370-timer", "marvell,armada-375-timer", "marvell,armada-xp-timer".
- interrupts: Should contain the list of Global Timer interrupts and
then local timer interrupts - reg: Should contain location and length for timers register. First
pair for the Global Timer registers, second pair for the
local/private timers.
Clocks required for compatible = “marvell,armada-370-timer”:
- clocks : Must contain a single entry describing the clock input
Clocks required for compatibles = “marvell,armada-xp-timer”,
“marvell,armada-375-timer”:
- clocks : Must contain an entry for each entry in clock-names.
- clock-names : Must include the following entries:
“nbclk” (L2/coherency fabric clock),
“fixed” (Reference 25 MHz fixed-clock).
Examples:
Armada 370:
timer {
compatible = "marvell,armada-370-timer"; reg = <0x20300 0x30>, <0x21040 0x30>; interrupts = <37>, <38>, <39>, <40>, <5>, <6>; clocks = <&coreclk 2>;
};
Armada XP:
timer {
compatible = "marvell,armada-xp-timer"; reg = <0x20300 0x30>, <0x21040 0x30>; interrupts = <37>, <38>, <39>, <40>, <5>, <6>; clocks = <&coreclk 2>, <&refclk>; clock-names = "nbclk", "fixed";
};