Kernel-4.18.0-80.el8_fixed-regulator

Fixed Voltage regulators

Required properties:

  • compatible: Must be “regulator-fixed”;
  • regulator-name: Defined in regulator.txt as optional, but required here.

Optional properties:

  • gpio: gpio to use for enable control
  • startup-delay-us: startup time in microseconds
  • enable-active-high: Polarity of GPIO is Active high
    If this property is missing, the default assumed is Active low.
  • gpio-open-drain: GPIO is open drain type.
    If this property is missing then default assumption is false.
  • vin-supply: Input supply name.

Any property defined as part of the core regulator
binding, defined in regulator.txt, can also be used.
However a fixed voltage regulator is expected to have the
regulator-min-microvolt and regulator-max-microvolt
to be the same.

Example:

abc: fixedregulator@0 {
    compatible = "regulator-fixed";
    regulator-name = "fixed-supply";
    regulator-min-microvolt = <1800000>;
    regulator-max-microvolt = <1800000>;
    gpio = <&gpio1 16 0>;
    startup-delay-us = <70000>;
    enable-active-high;
    regulator-boot-on;
    gpio-open-drain;
    vin-supply = <&parent_reg>;
};