The dm-integrity target emulates a block device that has additional
per-sector tags that can be used for storing integrity information.
A general problem with storing integrity tags with every sector is that
writing the sector and the integrity tag must be atomic - i.e. in case of
crash, either both sector and integrity tag or none of them is written.
To guarantee write atomicity, the dm-integrity target uses journal, it
writes sector data and integrity tags into a journal, commits the journal
and then copies the data and integrity tags to their respective location.
The dm-integrity target can be used with the dm-crypt target - in this
situation the dm-crypt target creates the integrity data and passes them
to the dm-integrity target via bio_integrity_payload attached to the bio.
In this mode, the dm-crypt and dm-integrity targets provide authenticated
disk encryption - if the attacker modifies the encrypted device, an I/O
error is returned instead of random data.
The dm-integrity target can also be used as a standalone target, in this
mode it calculates and verifies the integrity tag internally. In this
mode, the dm-integrity target can be used to detect silent data
corruption on the disk or in the I/O path.
When loading the target for the first time, the kernel driver will format
the device. But it will only format the device if the superblock contains
zeroes. If the superblock is neither valid nor zeroed, the dm-integrity
target can’t be loaded.
To use the target for the first time:
- overwrite the superblock with zeroes
- load the dm-integrity target with one-sector size, the kernel driver
will format the device - unload the dm-integrity target
- read the “provided_data_sectors” value from the superblock
- load the dm-integrity target with the the target size
“provided_data_sectors” - if you want to use dm-integrity with dm-crypt, load the dm-crypt target
with the size “provided_data_sectors”
Target arguments:
the underlying block device
the number of reserved sector at the beginning of the device - the
dm-integrity won’t read of write these sectorsthe size of the integrity tag (if “-“ is used, the size is taken from
the internal-hash algorithm)mode:
D - direct writes (without journal) - in this mode, journaling isnot used and data sectors and integrity tags are written separately. In case of crash, it is possible that the data and integrity tag doesn't match.
J - journaled writes - data and integrity tags are written to the
journal and atomicity is guaranteed. In case of crash, either both data and tag or none of them are written. The journaled mode degrades write throughput twice because the data have to be written twice.
R - recovery mode - in this mode, journal is not replayed,
checksums are not checked and writes to the device are not allowed. This mode is useful for data recovery if the device cannot be activated in any of the other standard modes.
the number of additional arguments
Additional arguments:
journal_sectors:number
The size of journal, this argument is used only if formatting the
device. If the device is already formatted, the value from the
superblock is used.
interleave_sectors:number
The number of interleaved sectors. This values is rounded down to
a power of two. If the device is already formatted, the value from
the superblock is used.
buffer_sectors:number
The number of sectors in one buffer. The value is rounded down to
a power of two.
The tag area is accessed using buffers, the buffer size is
configurable. The large buffer size means that the I/O size will
be larger, but there could be less I/Os issued.
journal_watermark:number
The journal watermark in percents. When the size of the journal
exceeds this watermark, the thread that flushes the journal will
be started.
commit_time:number
Commit time in milliseconds. When this time passes, the journal is
written. The journal is also written immediatelly if the FLUSH
request is received.
internal_hash:algorithm(:key) (the key is optional)
Use internal hash or crc.
When this argument is used, the dm-integrity target won’t accept
integrity tags from the upper target, but it will automatically
generate and verify the integrity tags.
You can use a crc algorithm (such as crc32), then integrity target
will protect the data against accidental corruption.
You can also use a hmac algorithm (for example
"hmac(sha256):0123456789abcdef"), in this mode it will provide
cryptographic authentication of the data without encryption.
When this argument is not used, the integrity tags are accepted
from an upper layer target, such as dm-crypt. The upper layer
target should check the validity of the integrity tags.
recalculate
Recalculate the integrity tags automatically. It is only valid
when using internal hash.
journal_crypt:algorithm(:key) (the key is optional)
Encrypt the journal using given algorithm to make sure that the
attacker can’t read the journal. You can use a block cipher here
(such as “cbc(aes)”) or a stream cipher (for example “chacha20”,
“salsa20”, “ctr(aes)” or “ecb(arc4)”).
The journal contains history of last writes to the block device,
an attacker reading the journal could see the last sector nubmers
that were written. From the sector numbers, the attacker can infer
the size of files that were written. To protect against this
situation, you can encrypt the journal.
journal_mac:algorithm(:key) (the key is optional)
Protect sector numbers in the journal from accidental or malicious
modification. To protect against accidental modification, use a
crc algorithm, to protect against malicious modification, use a
hmac algorithm with a key.
This option is not needed when using internal-hash because in this
mode, the integrity of journal entries is checked when replaying
the journal. Thus, modified sector number would be detected at
this stage.
block_size:number
The size of a data block in bytes. The larger the block size the
less overhead there is for per-block integrity metadata.
Supported values are 512, 1024, 2048 and 4096 bytes. If not
specified the default block size is 512 bytes.
The journal mode (D/J), buffer_sectors, journal_watermark, commit_time can
be changed when reloading the target (load an inactive table and swap the
tables with suspend and resume). The other arguments should not be changed
when reloading the target because the layout of disk data depend on them
and the reloaded target would be non-functional.
The layout of the formatted block device:
- reserved sectors (they are not used by this target, they can be used for
storing LUKS metadata or for other purpose), the size of the reserved
area is specified in the target arguments - superblock (4kiB)
- magic string - identifies that the device was formatted
- version
- log2(interleave sectors)
- integrity tag size
- the number of journal sections
- provided data sectors - the number of sectors that this target
provides (i.e. the size of the device minus the size of all
metadata and padding). The user of this target should not send
bios that access data beyond the “provided data sectors” limit. - flags - a flag is set if journal_mac is used
- journal
The journal is divided into sections, each section contains:- metadata area (4kiB), it contains journal entries
every journal entry contains:- logical sector (specifies where the data and tag should
be written) - last 8 bytes of data
- integrity tag (the size is specified in the superblock)
every metadata sector ends with - mac (8-bytes), all the macs in 8 metadata sectors form a
64-byte value. It is used to store hmac of sector
numbers in the journal section, to protect against a
possibility that the attacker tampers with sector
numbers in the journal. - commit id
- logical sector (specifies where the data and tag should
- data area (the size is variable; it depends on how many journal
entries fit into the metadata area)
every sector in the data area contains:- data (504 bytes of data, the last 8 bytes are stored in
the journal entry) - commit id
To test if the whole journal section was written correctly, every
512-byte sector of the journal ends with 8-byte commit id. If the
commit id matches on all sectors in a journal section, then it is
assumed that the section was written correctly. If the commit id
doesn’t match, the section was written partially and it should not
be replayed.
- data (504 bytes of data, the last 8 bytes are stored in
- metadata area (4kiB), it contains journal entries
- one or more runs of interleaved tags and data. Each run contains:
- tag area - it contains integrity tags. There is one tag for each
sector in the data area - data area - it contains data sectors. The number of data sectors
in one run must be a power of two. log2 of this value is stored
in the superblock.
- tag area - it contains integrity tags. There is one tag for each